Fireye
Fireye

Fireye Flame Safeguard & Combustion Control Equipment $100 net minimum order applies. Drop ship charge of $50.00 per order. All quoted prices will be in U.S. dollars.

Pyromation
Pyromation

Pyromation began operations in 1962 and is one of the leading manufacturers of thermocouples, RTDs, PT100s and thermowells in North America. As an ISO 9001-registered company, Advanced Manufacturing Firm and Lean enterprise with an onsite NVLA […]

Siemens
Siemens

Combustion Components

Manufacturers

Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure
Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure

MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners

Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge
Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge

MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Approval.

Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed
Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed

MEP109 Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non‐recycle on flame fail.

Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.
Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals
Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.
Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

Fireye MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.
Fireye MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

Fireye MEP230 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start.
Fireye MEP230 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start.

MEP230 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start.

Fireye MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.
Fireye MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.

MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.

Fireye MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non ‐ recycle lockout on air flow open af […]

Fireye MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second igniter on time with main fuel. To be used with intermittent pilot only

Fireye MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition deenergized 3 seconds after pilot detected. Provides 8 second pilot stabilization period.

Fireye MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start
Fireye MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start

MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds).

Fireye MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge
Fireye MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge

MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge.