Fireye Flame Safeguard & Combustion Control Equipment $100 net minimum order applies. Drop ship charge of $50.00 per order. All quoted prices will be in U.S. dollars.

Pyromation
Pyromation

Pyromation began operations in 1962 and is one of the leading manufacturers of thermocouples, RTDs, PT100s and thermowells in North America. As an ISO 9001-registered company, Advanced Manufacturing Firm and Lean enterprise with an onsite NVLA […]

Siemens
Siemens

Combustion Components

Manufacturers

Fireye MEP537 Same as MEP536 except provides one recycle on main flame fail
Fireye MEP537 Same as MEP536 except provides one recycle on main flame fail

MEP537 Same as MEP536 except provides one recycle on main flame fail.

Fireye MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, run‐check switch.

Fireye MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start.
Fireye MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start.

MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start, 10 sec main trial for ignition, run‐check switch.

Fireye MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start.
Fireye MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start.

MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, with lockout on loss of air flow. Non‐recycle, run‐check switch.

Fireye MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.
Fireye MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.

MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.

Fireye MEP300 Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail
Fireye MEP300 Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail

MEP300 Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail, 10 sec PTFI (fixed), 5 sec pilot proving, 5 sec MTFI.

Fireye MEP304 Programmer, 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving
Fireye MEP304 Programmer, 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving

MEP304 Programmer, 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving, 10 sec MTFI, interrupted pilot, interrupted ignition, non-recycle on flame fail.

Fireye MEP397 Programmer, 15 sec purge, provides interrupted ignition, interrupted pilot, non recycle on flame fail
Fireye MEP397 Programmer, 15 sec purge, provides interrupted ignition, interrupted pilot, non recycle on flame fail

MEP397 Programmer, 15 sec purge, provides interrupted ignition, interrupted pilot, non recycle on flame fail.

Fireye MEP437 Programmer, Valve proof of closure, selectable purge, PTFI timing, intermittent or interrupted, recycle / non‐recycle operation
Fireye MEP437 Programmer, Valve proof of closure, selectable purge, PTFI timing, intermittent or interrupted, recycle / non‐recycle operation

MEP437 Programmer, Valve proof of closure, selectable purge, PTFI timing, intermittent or interrupted, recycle / non‐recycle operation, reset by power interruption of manual reset.

Fireye MEP696 Programmer  For use with MEC320TS chassis only.
Fireye MEP696 Programmer For use with MEC320TS chassis only.

MEP696 Programmer, provides selectable PTFI, selectable baud rate, and selectable recycle / non‐recycle operation. For use with MEC320TS chassis only.

Fireye MEP697 Programmer Selectable TFI timing, purge timing, post purge, prove open at start, and recycle / non‐recycle on flame fail
Fireye MEP697 Programmer Selectable TFI timing, purge timing, post purge, prove open at start, and recycle / non‐recycle on flame fail

MEP697 Programmer Selectable TFI timing, purge timing, post purge, prove open at start, and recycle / non‐recycle on flame fail. Includes 5 sec pilot proving, early spark termination, 10 sec MTFI, and interrupted pilot.

Fireye MEUV1 UV amp, 0.8 sec FFRT. Use with UV1, UV2, 45UV3.
Fireye MEUV1 UV amp, 0.8 sec FFRT. Use with UV1, UV2, 45UV3.

MEUV1 UV amp, 0.8 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MEUV4 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.
Fireye MEUV4 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.

MEUV4 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MEUVS1 UV self check amp, 0.8 sec FFRT. Use with 45UV5‐1008, ‐1009.
Fireye MEUVS1 UV self check amp, 0.8 sec FFRT. Use with 45UV5‐1008, ‐1009.

MEUVS1 UV self check amp, 0.8 sec FFRT. Use with 45UV5‐1008, ‐1009.

Fireye MEUVS4 UV self check amp, 3 sec FFRT. Use with 45UV5‐1008, ‐1009.
Fireye MEUVS4 UV self check amp, 3 sec FFRT. Use with 45UV5‐1008, ‐1009.

MEUVS4 UV self check amp, 3 sec FFRT. Use with 45UV5‐1008, ‐1009.