Components

Manufacturers

Fireye
Fireye

Fireye Flame Safeguard & Combustion Control Equipment $100 net minimum order applies. Drop ship charge of $50.00 per order. All quoted prices will be in U.S. dollars.

Pyromation
Pyromation

Pyromation began operations in 1962 and is one of the leading manufacturers of thermocouples, RTDs, PT100s and thermowells in North America. As an ISO 9001-registered company, Advanced Manufacturing Firm and Lean enterprise with an onsite NVLA […]

Siemens
Siemens

Combustion Components

Manufacturers

Fireye MERT1 Flame rect amp. 0.8 sec FFRT. Use with 69ND, 45CM.
Fireye MERT1 Flame rect amp. 0.8 sec FFRT. Use with 69ND, 45CM.

MEUV4 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MERT4 Flame rect amp. 3 sec FFRT. Use with 69ND, 45CM.
Fireye MERT4 Flame rect amp. 3 sec FFRT. Use with 69ND, 45CM.

MERT4 Flame rect amp. 3 sec FFRT. Use with 69ND, 45CM.

Fireye MEIR1 Infrared amp, 0.8 sec FFRT. Use with 48PT2 scanner.
Fireye MEIR1 Infrared amp, 0.8 sec FFRT. Use with 48PT2 scanner.

MEIR1 Infrared amp, 0.8 sec FFRT. Use with 48PT2 scanner.

Fireye MEIR4 Infrared amp, 3 sec FFRT. Use with 48PT2 scanner.
Fireye MEIR4 Infrared amp, 3 sec FFRT. Use with 48PT2 scanner.

MEIR4 Infrared amp, 3 sec FFRT. Use with 48PT2 scanner.

Fireye MECD1 Cadmium sulfide amp, 0.8 sec FFRT. Use with C554A scanner.
Fireye MECD1 Cadmium sulfide amp, 0.8 sec FFRT. Use with C554A scanner.

MECD1 Cadmium sulfide amp, 0.8 sec FFRT. Use with C554A scanner.

Fireye MECD4 Cadmium sulfide amp, 3 sec FFRT. Use with C554A scanner.
Fireye MECD4 Cadmium sulfide amp, 3 sec FFRT. Use with C554A scanner.

MECD4 Cadmium sulfide amp, 3 sec FFRT. Use with C554A scanner.

Fireye MEP237 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP237 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP237 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start. Provides 0.30 second flame failure response time, for use with Phoenix and InSight flame scanner and MEDC2 amplifier.

Fireye MEDC2 Amplifier for use with dry contact input from 85UVF‐WR flame scanner
Fireye MEDC2 Amplifier for use with dry contact input from 85UVF‐WR flame scanner

MEDC2 Amplifier for use with dry contact input from 85UVF‐WR flame scanner, 0.30 sec FFRT. Use with MEP237 and 85UVF4‐1QDWR, 85IRF4‐1QDWR, or InSight scanner (with 59‐497‐020WR cable).

Fireye MED1 Standard daughter board, local reset switch.
Fireye MED1 Standard daughter board, local reset switch.

MED1 Standard daughter board, local reset switch.

Fireye MED2 Daughter board with local reset switch, display output.
Fireye MED2 Daughter board with local reset switch, display output.

MED2 Daughter board with local reset switch, display output.

Fireye MED3 Daughter board with local reset switch, remote reset.
Fireye MED3 Daughter board with local reset switch, remote reset.

MED3 Daughter board with local reset switch, remote reset.

Fireye MED4 Daughter board with local reset switch, display output and remote reset.
Fireye MED4 Daughter board with local reset switch, display output and remote reset.

MED4 Daughter board with local reset switch, display output and remote reset.

Fireye MED5 Daughter board with local reset switch, display output and communications.
Fireye MED5 Daughter board with local reset switch, display output and communications.

MED5 Daughter board with local reset switch, display output and communications.

Fireye MED6 Daughter board with local reset switch, display output, remote reset, and communications.
Fireye MED6 Daughter board with local reset switch, display output, remote reset, and communications.

MED6 Daughter board with local reset switch, display output, remote reset, and communications.

Fireye MED7 Daughter board with local reset switch, communications.
Fireye MED7 Daughter board with local reset switch, communications.

MED7 Daughter board with local reset switch, communications.