All BurnerPro
BurnerPRO Flame Safeguard
The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels.
BurnerPRO Flame Safeguard (BP110UVF/BP230UVF) Control, with integrated flame safeguard and boiler control operation, provides simplified operation for single-point applications.
The system is designed for use in non-permanent operations that requires burner recycle at least once every 24 hours. Seven SMART LEDs provide current operating status and lockout information in the event of a safety shutdown.
BurnerPro Subcategories
The Fireye BurnerPRO is a compact, microprocessor based, primary flame safeguard control system designed to provide the proper burner sequencing, ignition and flame monitoring for on-off, multistage, or modulating burners used in commercial he […]
MAIN CONTROL – UV / FR with ModBus to replace Honeywell RM7800 / RM7895
BurnerPro Components
BP110UVFR‐S11M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60‐2991‐1. , Default timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 10 sec. UV non‐self check and FR amplifier, IP40. […]
BP110UVFR‐S12M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60‐2991‐1. , Default timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 15 sec. U non‐self check and FR amplifier, IP40. […]
BP110UVFR‐S13M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60‐2991‐2. , Default timings: Purge = 5 sec, PTFI = 5 sec, MTFI = 10 sec. UV nonself check and FR amplifier, IP40 […]
BP110UVFR‐S14M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60‐2991‐2. , Default timings: Purge = 5 sec, PTFI = 10 sec, MTFI = 15 sec. UV non‐self check and FR amplifier, IP40. […]
BP110UVFR‐S1M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 1 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐ 981‐1 and Siemens LFL wiring base
BP110UVFR‐S2M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 2 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S3M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 3 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S4M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 4 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S5M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 5 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S6M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 6 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐SXM BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Flexible Series timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP230UVFR‐S1M BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 1 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP230UVFR‐S2M BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 2 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base