All M‐SERIES II

Fireye® Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels.

M‐SERIES II Subcategories

M-SERIES II ACCESSORIES
M-SERIES II ACCESSORIES

M-SERIES II AMPLIFIER MODULES
M-SERIES II AMPLIFIER MODULES

M-SERIES II CHASSIS
M-SERIES II CHASSIS

M-SERIES II PROGRAMMER MODULES
M-SERIES II PROGRAMMER MODULES

The Fireye MP100, MP100E, MP101, MP102, MP102E, MP230, MP230H, MP560, MP561 and MP562 Programmer Modules are used with the Fireye Modular M-Series II control. The operational characteristics of the control are determined by the selection of th […]

M‐SERIES II Components

Manufacturers

Fireye MC120 120 VAC, 50/60 Hz Chassis.
Fireye MC120 120 VAC, 50/60 Hz Chassis.

MC120 120 VAC, 50/60 Hz Chassis.

Fireye MC120P 120 VAC, 50/60 Hz Chassis with remote reset and post purge.
Fireye MC120P 120 VAC, 50/60 Hz Chassis with remote reset and post purge.

MC120P 120 VAC, 50/60 Hz Chassis with remote reset and post purge.

Fireye MC120R 120 VAC, 50/60 Hz Chassis with remote reset.
Fireye MC120R 120 VAC, 50/60 Hz Chassis with remote reset.

MC120R 120 VAC, 50/60 Hz Chassis with remote reset.

Fireye MC230 230 VAC Chassis. Meets European EN230, EN298 approval.
Fireye MC230 230 VAC Chassis. Meets European EN230, EN298 approval.

MC230 230 VAC Chassis. Meets European EN230, EN298 approval.

Fireye MP100 Programmer, Relight function.
Fireye MP100 Programmer, Relight function.

MP100 Programmer, Relight function.

Fireye MP101 Programmer, Relight function. Will ignore flame signal during “off” cycle.
Fireye MP101 Programmer, Relight function. Will ignore flame signal during “off” cycle.

MP101 Programmer, Relight function. Will ignore flame signal during “off” cycle.

Fireye MP230 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing.
Fireye MP230 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing.

MP230 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing.

Fireye MP230H Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot stabilization, two stage capability.
Fireye MP230H Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot stabilization, two stage capability.

MP230H Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot stabilization, two stage capability..

Fireye MP560 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, pilot stabilization, check-run switch.
Fireye MP560 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, pilot stabilization, check-run switch.

MP560 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, pilot stabilization, check-run switch.

Fireye MP561 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, check-run switch
Fireye MP561 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, check-run switch

MP561 Programmer, Selectable recycle/non-recycle function, TFI, and purge timing. Pilot cutoff, check-run switch

Fireye MP562 Programmer, Selectable TFI, and purge timing. Pilot cutoff, pilot stabilization, lockout on loss of air flow, non-recycle, check-run switch.
Fireye MP562 Programmer, Selectable TFI, and purge timing. Pilot cutoff, pilot stabilization, lockout on loss of air flow, non-recycle, check-run switch.

MP562 Programmer, Selectable TFI, and purge timing. Pilot cutoff, pilot stabilization, lockout on loss of air flow, non-recycle, check-run switch.

Fireye MAUV1 UV amp, 2‐4 sec FFRT. Use with UV1, UV2, 45UV3.
Fireye MAUV1 UV amp, 2‐4 sec FFRT. Use with UV1, UV2, 45UV3.

MAUV1 UV amp, 2‐4 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MAUV1T UV amp, .8 sec FFRT. Use with UV1, UV2, 45UV3.
Fireye MAUV1T UV amp, .8 sec FFRT. Use with UV1, UV2, 45UV3.

MAUV1T UV amp, .8 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MAUV3 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.
Fireye MAUV3 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.

MAUV3 UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.

Fireye MART1 Flame rect amp. 2‐4 sec FFRT. Use with 69ND, 45CM
Fireye MART1 Flame rect amp. 2‐4 sec FFRT. Use with 69ND, 45CM