All MICROM PROGRAMMER MODULES

The Fireye MEP100, MEP100P, MEP101, MEP102, MEP103, MEP104, MEP105, MEP106 MEP107,MEP108, ME109, MEP130, MEP141 and MEP149 Programmer Modules are used with the Fireye Modular MicroM control. The operational characteristics of the control are determined by the selection of theprogrammer module (e.g. re-light, 2-stage capability, pilot cutoff, etc.). The programmer module incorporates a plug-in design for easy installation.

Manufacturers

Fireye MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.
Fireye MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.

MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.

Fireye MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non ‐ recycle lockout on air flow open af […]

Fireye MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second igniter on time with main fuel. To be used with intermittent pilot only

Fireye MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition deenergized 3 seconds after pilot detected. Provides 8 second pilot stabilization period.

Fireye MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start
Fireye MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start

MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds).

Fireye MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge
Fireye MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge

MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge.

Fireye MEP537 Same as MEP536 except provides one recycle on main flame fail
Fireye MEP537 Same as MEP536 except provides one recycle on main flame fail

MEP537 Same as MEP536 except provides one recycle on main flame fail.

Fireye MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start
Fireye MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start

MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, run‐check switch.

Fireye MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start.
Fireye MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start.

MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start, 10 sec main trial for ignition, run‐check switch.

Fireye MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start.
Fireye MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start.

MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, with lockout on loss of air flow. Non‐recycle, run‐check switch.

Fireye MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.
Fireye MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.

MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.