All MICROM SERIES

The Fireye MicroM Series Flame Safeguard Control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment that use gas and/or light oil fuels.

MICROM SERIES Subcategories

MICROM ACCESSORIES
MICROM ACCESSORIES

MICROM AMPLIFIER MODULES
MICROM AMPLIFIER MODULES

MICROM CHASSIS MEC320 CHASSIS FOR USE WITH MEP300 AND 600 SERIES PROGRAMMERS
MICROM CHASSIS MEC320 CHASSIS FOR USE WITH MEP300 AND 600 SERIES PROGRAMMERS

MICROM CHASSIS TYPES FOR USE WITH MEP100, 200, AND 500 SERIES PROGRAMMERS
MICROM CHASSIS TYPES FOR USE WITH MEP100, 200, AND 500 SERIES PROGRAMMERS

MICROM PROGRAMMER MODULES
MICROM PROGRAMMER MODULES

The Fireye MEP100, MEP100P, MEP101, MEP102, MEP103, MEP104, MEP105, MEP106 MEP107,MEP108, ME109, MEP130, MEP141 and MEP149 Programmer Modules are used with the Fireye Modular MicroM control. The operational characteristics of the control are d […]

PLUG-IN DAUGHTER BOARDS
PLUG-IN DAUGHTER BOARDS

PROGRAMMERS AND FLAME AMPLIFIERS FOR USE WITH INTEGRATED FLAME SCANNERS
PROGRAMMERS AND FLAME AMPLIFIERS FOR USE WITH INTEGRATED FLAME SCANNERS

PROGRAMMERS FOR USE WITH MEC320 / MEC480 CHASSIS
PROGRAMMERS FOR USE WITH MEC320 / MEC480 CHASSIS

The Fireye MEP300, MEP304, MEP335 and MEP397 Programmer Modules are used with the Fireye Modular MicroM control. The MEP300 series programmers provide additional enhancements such as early spark termination, pilot proving and interrupted or in […]

MICROM SERIES Components

Manufacturers

Fireye MEC320TS MicroM MEC320 chassis with remote communications and independent relay output
Fireye MEC320TS MicroM MEC320 chassis with remote communications and independent relay output

MEC320TS MicroM MEC320 chassis with remote communications and independent relay output. For use with MEP300 and 600 series programmers. Use with MEP696 programmer only.

Fireye MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz
Fireye MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz

MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz, provides independent relay outputs on terminals 3 and 4. For use with MEP300 and 600 series programmers.

Fireye MEP100 Programmer, Relight function, 10 sec PTFI.
Fireye MEP100 Programmer, Relight function, 10 sec PTFI.

MEP100 Programmer, Relight function, 10 sec PTFI.

Fireye MEP101 Programmer, Relight function
Fireye MEP101 Programmer, Relight function

MEP101 Programmer, Relight function, allow flame signal until 60 seconds after interlock circuit closes.

Fireye MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.
Fireye MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.

MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.

Fireye MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge
Fireye MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge

MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge. *Spark Igniter Sensing Period

Fireye MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.
Fireye MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.

MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.

Fireye MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.
Fireye MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.

MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.

Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure
Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure

MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners

Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge
Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge

MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Approval.

Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed
Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed

MEP109 Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non‐recycle on flame fail.

Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.
Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals
Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.
Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.