All Burner Controls
Fireye provides a variety of burner control flame safeguard and combustion controls. Our BurnerPRO™, BurnerLogix™, Flame-Monitor™ and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired makeup air units and commercial hot water heaters.
Burner Controls Subcategories
The Fireye BurnerLogixTM System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection onautomatically ignited oil, gas, and combination fuel burner […]
BurnerPRO Flame Safeguard The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels. BurnerPRO Flame Safeguard (BP110UVF/BP230UVF) Contr […]
D-Series 70D40 and 70D41 Burner Control Fireye Series D10, D20 and D30 burner management controls provide ignition and main flame failure protection for automatically ignited oil and gas burners. Plug-in Amplifier Modules permit the selection […]
The Fireye® FLAME-MONITOR™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring pro-tection on automatically ignited oil, gas, and combination fuel bu […]
Fireye Flame Scanners provides a variety of UV and IR flame scanners that accurately detect the presence or absence of flame in a combustion chamber and some provide both self-check and non-self check capabilities.
The inTouch Wireless Monitoring System provides continuous monitoring for up to 10 Flame-Monitor, MicroM and/or BurnerLogix flame safeguard controls. The inTouch System provides 4 dry-contact andAC power inputs. In the event of a lockout or co […]
Fireye® Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use g […]
Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels. The M4RT1/M4RT24 control incorporates a safety checking circuit that is […]
Burner Controls Components
BP230UV‐S2 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 2 timings, with UV non‐self check amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP230UV‐S3 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 3 timings, with UV non‐self check amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP230UV‐S6 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 6 timings (EP160), with UV non‐self check amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S1 BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 1 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP110UVFR‐S2 BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 2 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP110UVFR‐S3 BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 3 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP110UVFR‐S5 BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 5 timings (S3 timings with 4 sec FFRT), with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base
BP230UVFR‐S1 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 1 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP230UVFR‐S2 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 2 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP230UVFR‐S3 BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 3 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981 and Siemens LFL wiring base
BP110UVFR‐S11M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60‐2991‐1. , Default timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 10 sec. UV non‐self check and FR amplifier, IP40. […]
BP110UVFR‐S12M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60‐2991‐1. , Default timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 15 sec. U non‐self check and FR amplifier, IP40. […]
BP110UVFR‐S13M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60‐2991‐2. , Default timings: Purge = 5 sec, PTFI = 5 sec, MTFI = 10 sec. UV nonself check and FR amplifier, IP40 […]
BP110UVFR‐S14M BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60‐2991‐2. , Default timings: Purge = 5 sec, PTFI = 10 sec, MTFI = 15 sec. UV non‐self check and FR amplifier, IP40. […]