Fireye provides a variety of burner control flame safeguard and combustion controls. Our BurnerPRO™, BurnerLogix™, Flame-Monitor™ and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired makeup air units and commercial hot water heaters.

Burner Controls Subcategories

BurnerLogix
BurnerLogix

The Fireye BurnerLogixTM System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection onautomatically ignited oil, gas, and combination fuel burner […]

BurnerPro
BurnerPro

BurnerPRO Flame Safeguard The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels. BurnerPRO Flame Safeguard (BP110UVF/BP230UVF) Contr […]

D‐SERIES
D‐SERIES

D-Series 70D40 and 70D41 Burner Control Fireye Series D10, D20 and D30 burner management controls provide ignition and main flame failure protection for automatically ignited oil and gas burners. Plug-in Amplifier Modules permit the selection […]

FLAME MONITOR
FLAME MONITOR

The Fireye® FLAME-MONITOR™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring pro-tection on automatically ignited oil, gas, and combination fuel bu […]

Flame Scanners
Flame Scanners

Fireye Flame Scanners provides a variety of UV and IR flame scanners that accurately detect the presence or absence of flame in a combustion chamber and some provide both self-check and non-self check capabilities.

INTOUCH
INTOUCH

The inTouch Wireless Monitoring System provides continuous monitoring for up to 10 Flame-Monitor, MicroM and/or BurnerLogix flame safeguard controls. The inTouch System provides 4 dry-contact andAC power inputs. In the event of a lockout or co […]

M‐SERIES II
M‐SERIES II

Fireye® Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use g […]

M4RT1/M4RT24
M4RT1/M4RT24

Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels. The M4RT1/M4RT24 control incorporates a safety checking circuit that is […]

MICROM SERIES
MICROM SERIES

The Fireye MicroM Series Flame Safeguard Control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment […]

NEXUS
NEXUS

Our Nexus® family of products is used in boiler applications to not only provide the flame safeguard function, but also control the entire burner operation in a manner which greatly improves efficiency and lowers operational costs. Optional va […]

Burner Controls Components

Manufacturers

Fireye PXMS‐15 Steam Pressure Sensor: 0 ‐ 15 PSI OBSOLETE ‐ REPLACE WITH PXMS‐15K
Fireye PXMS‐15 Steam Pressure Sensor: 0 ‐ 15 PSI OBSOLETE ‐ REPLACE WITH PXMS‐15K

PXMS‐15 Steam Pressure Sensor: 0 ‐ 15 PSI, 4‐20mA output, 1/2″ NPT, OBSOLETE ‐ REPLACE WITH PXMS‐15K

Fireye PXMS‐200 Steam Pressure Sensor: 0 ‐ 200 PSI OBSOLETE
Fireye PXMS‐200 Steam Pressure Sensor: 0 ‐ 200 PSI OBSOLETE

PXMS‐200 Steam Pressure Sensor: 0 ‐ 200 PSI, 4‐20mA output, 1/2″ NPT, OBSOLETE ‐ REPLACE WITH PXMS‐200K

Fireye PXMS‐300 Steam Pressure Sensor OBSOLETE ‐ REPLACE WITH PXMS‐300K
Fireye PXMS‐300 Steam Pressure Sensor OBSOLETE ‐ REPLACE WITH PXMS‐300K

PXMS‐300 Steam Pressure Sensor: 0 ‐ 300 PSI, 4‐20mA output, 1/2″ NPT, OBSOLETE ‐ REPLACE WITH PXMS‐300K

Fireye PXMS‐15K Steam Pressure Sensor: 0 ‐ 15 PSI
Fireye PXMS‐15K Steam Pressure Sensor: 0 ‐ 15 PSI

PXMS‐15K Steam Pressure Sensor: 0 ‐ 15 PSI, 0 ‐ 1 bar, 4‐20mA output, 1/2″ NPT, non self‐check.

Fireye PXMS‐200K Steam Pressure Sensor: 0 ‐ 200 PSI
Fireye PXMS‐200K Steam Pressure Sensor: 0 ‐ 200 PSI

PXMS‐200K Steam Pressure Sensor: 0 ‐ 200 PSI, 0 ‐ 14 bar, 4‐20mA output, 1/2″ NPT, non self‐check.

Fireye PXMS‐300K Steam Pressure Sensor: 0 ‐ 300 PSI
Fireye PXMS‐300K Steam Pressure Sensor: 0 ‐ 300 PSI

PXMS‐300K Steam Pressure Sensor: 0 ‐ 300 PSI, 0 ‐ 21 bar, 4‐20mA output, 1/2″ NPT, non self‐check.

Fireye NX1021‐1 Gas Pressure Sensor
Fireye NX1021‐1 Gas Pressure Sensor

NX1021‐1 Gas Pressure Sensor with self test feature: 0 ‐ 8.8 PSI, 0 ‐ 244″ w.c., 0 ‐ 600 millibar, 1/2″ NPT.

Fireye NX1021‐2 Gas Pressure Sensor
Fireye NX1021‐2 Gas Pressure Sensor

NX1021‐2 Gas Pressure Sensor with self test feature: 0 ‐ 8.8 PSI, 0 ‐ 244″ w.c., 0 ‐ 600 millibar, 1/4″ BSP.

Fireye NX1034‐1 Steam Pressure Sensor
Fireye NX1034‐1 Steam Pressure Sensor

NX1034‐1 Steam Pressure Sensor with self test feature: 0 ‐ 58 PSI, 0 ‐ 4 bar, 1/4″ BSP. Includes 1/4″ female BSP to 1/2″ NPT male adapter.

Fireye NX1034‐2 Steam Pressure Sensor
Fireye NX1034‐2 Steam Pressure Sensor

NX1034‐2 Steam Pressure Sensor with self test feature: 0 ‐ 58 PSI, 0 ‐ 4 bar, 1/4″ BSP.

Fireye NX1030‐1 Steam Pressure Sensor
Fireye NX1030‐1 Steam Pressure Sensor

NX1030‐1 Steam Pressure Sensor with self test feature: 0 ‐ 362.5 PSI, 0 ‐ 25 bars, 1/2″ NPT.

Fireye NX1030‐2 Steam Pressure Sensor
Fireye NX1030‐2 Steam Pressure Sensor

NX1030‐2 Steam Pressure Sensor with self test feature: 0 ‐ 362.5 PSI, 0 ‐ 25 bars, 1/4″ BSP.

Fireye NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect, motor overload relay, and backlit LCD display and keypad.
Fireye NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect, motor overload relay, and backlit LCD display and keypad.

NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect, motor overload relay, and backlit LCD display and keypad. NXVFD54A NXVFD74A NXVFD104A NXVFD154A NXVFD204A NXVFD254A NXVFD304A NXVFD404A NXVFD504A NXVFD604A NXVFD754A NXVFD1004A […]

Fireye NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect with 3 contactor by-pass package (120 VAC control transformer, door mounted Drive/Off/Bypass/Test selector switch and red “Bypass On” pilot light), and backlit LCD display and keypad.
Fireye NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect with 3 contactor by-pass package (120 VAC control transformer, door mounted Drive/Off/Bypass/Test selector switch and red “Bypass On” pilot light), and backlit LCD display and keypad.

NXVFD Variable speed drives in NEMA 12 cabinet, fused disconnect with 3 contactor by-pass package (120 VAC control transformer, door mounted Drive/Off/Bypass/Test selector switch and red “Bypass On” pilot light), and backlit LCD display and ke […]

Fireye MEC120 120 VAC, 50/60 Hz Chassis with standard plug‐in daughter board
Fireye MEC120 120 VAC, 50/60 Hz Chassis with standard plug‐in daughter board

MEC120 120 VAC, 50/60 Hz Chassis with standard plug‐in daughter board