All Burner Controls
Fireye provides a variety of burner control flame safeguard and combustion controls. Our BurnerPRO™, BurnerLogix™, Flame-Monitor™ and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired makeup air units and commercial hot water heaters.
Burner Controls Subcategories
The Fireye BurnerLogixTM System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection onautomatically ignited oil, gas, and combination fuel burner […]
BurnerPRO Flame Safeguard The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels. BurnerPRO Flame Safeguard (BP110UVF/BP230UVF) Contr […]
D-Series 70D40 and 70D41 Burner Control Fireye Series D10, D20 and D30 burner management controls provide ignition and main flame failure protection for automatically ignited oil and gas burners. Plug-in Amplifier Modules permit the selection […]
The Fireye® FLAME-MONITOR™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring pro-tection on automatically ignited oil, gas, and combination fuel bu […]
Fireye Flame Scanners provides a variety of UV and IR flame scanners that accurately detect the presence or absence of flame in a combustion chamber and some provide both self-check and non-self check capabilities.
The inTouch Wireless Monitoring System provides continuous monitoring for up to 10 Flame-Monitor, MicroM and/or BurnerLogix flame safeguard controls. The inTouch System provides 4 dry-contact andAC power inputs. In the event of a lockout or co […]
Fireye® Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use g […]
Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels. The M4RT1/M4RT24 control incorporates a safety checking circuit that is […]
Burner Controls Components
MEP230 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start.
MEP230H Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.
MEP235 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non ‐ recycle lockout on air flow open af […]
MEP236 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second igniter on time with main fuel. To be used with intermittent pilot only
MEP238 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition deenergized 3 seconds after pilot detected. Provides 8 second pilot stabilization period.
MEP290 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds).
MEP536 Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge.
MEP537 Same as MEP536 except provides one recycle on main flame fail.
MEP560 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, run‐check switch.
MEP561 Programmer, Selectable recycle/non‐recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start, 10 sec main trial for ignition, run‐check switch.
MEP562 Programmer, Selectable TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, with lockout on loss of air flow. Non‐recycle, run‐check switch.
MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.
MEP300 Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail, 10 sec PTFI (fixed), 5 sec pilot proving, 5 sec MTFI.