All Fireye

Fireye Flame Safeguard & Combustion Control Equipment

$100 net minimum order applies. Drop ship charge of $50.00 per order. All quoted prices will be in U.S. dollars.

Fireye Subcategories

Burner Controls
Burner Controls

Fireye provides a variety of burner control flame safeguard and combustion controls. Our BurnerPRO™, BurnerLogix™, Flame-Monitor™ and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boi […]

Fireye Components

Manufacturers

Fireye  BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 5 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP110UVFR‐S5MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 5 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP110UVFR‐S6MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP110UVFR‐S6MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP110UVFR‐S6MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 6 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP110UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP110UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP110UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Flexible Series timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP230UVFR‐S1MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP230UVFR‐S1MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP230UVFR‐S1MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 1 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP230UVFR‐S2MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP230UVFR‐S2MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP230UVFR‐S2MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 2 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP230UVFR‐S3MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP230UVFR‐S3MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP230UVFR‐S3MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 3 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP230UVFR‐S4MP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP230UVFR‐S4MP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP230UVFR‐S4MP BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 4 timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye  BP230UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving
Fireye BP230UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving

BP230UVFR‐SXMP BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Flexible Series timings, with UV non‐self check and FR amplifier, IP40. Compatible with 60‐2981‐1 and Siemens LFL wiring base

Fireye 60‐2981‐1 WIRING BASE Open base with terminal block
Fireye 60‐2981‐1 WIRING BASE Open base with terminal block

60‐2981‐1 Open base with terminal block and PG11 knockouts w/ grounding leash, 4.1” L x 4.1” W x 1.2” H.

Fireye 60‐2981‐M16 WIRING BASE Open base with terminal block
Fireye 60‐2981‐M16 WIRING BASE Open base with terminal block

60‐2981‐M16 Open base with terminal block and M16 knockouts w/ grounding leash, 4.1” L x 4.1” W x 1.2” H.

Fireye 60‐2991‐1 Wiring harness
Fireye 60‐2991‐1 Wiring harness

60‐2991‐1 Wiring harness to convert RM7800 / RM7840 / RM7845 (less valve proving) to Fireye BurnerPRO.

Fireye 60‐2991‐2 Wiring harness
Fireye 60‐2991‐2 Wiring harness

60‐2991‐2 Wiring harness to convert RM7895 to Fireye BurnerPRO.

Fireye UV90L‐1 UV scanner BurnerPro
Fireye UV90L‐1 UV scanner BurnerPro

UV90L‐1 UV scanner, Front and side (90o) lateral view, terminal block hook‐up

Fireye UV1AL UV scanner BurnerPro
Fireye UV1AL UV scanner BurnerPro

UV1AL UV scanner, 1/2” NPT connector, front view, 3 ft or 6 ft cable, shielded leads