Fireye MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz
Fireye MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz

MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz, provides independent relay outputs on terminals 3 and 4. For use with MEP300 and 600 series programmers.

Fireye MEP100 Programmer, Relight function, 10 sec PTFI.
Fireye MEP100 Programmer, Relight function, 10 sec PTFI.

MEP100 Programmer, Relight function, 10 sec PTFI.

Fireye MEP101 Programmer, Relight function
Fireye MEP101 Programmer, Relight function

MEP101 Programmer, Relight function, allow flame signal until 60 seconds after interlock circuit closes.

Fireye MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.
Fireye MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.

MEP102 Programmer, Non‐recycle on flame fail, 5 second PTFI.

Fireye MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge
Fireye MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge

MEP103 Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re‐try once on pilot failure, fixed 30 sec post purge. *Spark Igniter Sensing Period

Fireye MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.
Fireye MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.

MEP104 Programmer, Non‐recycle on flame fail, 10 second PTFI.

Fireye MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.
Fireye MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.

MEP105 Programmer, Non‐recycle on flame fail, lockout on air‐flow open with flame present, 10 second PTFI.

Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
Fireye MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.

Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure
Fireye MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure

MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners

Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge
Fireye MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge

MEP108 Non‐recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Approval.

Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed
Fireye MEP109 Programmer, Immediate ignition and pilot after limits are closed

MEP109 Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non‐recycle on flame fail.

Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.
Fireye MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

MEP100P Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.

Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals
Fireye MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

MEP130 Programmer, Relight operation, 30 sec PTFI, no agency approvals

Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.
Fireye MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

MEP141 Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

Fireye MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.
Fireye MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.

MEP149 Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non‐recycle on flame fail.