For your Fireye component part needs search our site or call us Toll Free  800-752-3697

Fireye provides a variety of burner control flame safeguard and combustion controls. Our BurnerPRO™, BurnerLogix™, Flame-Monitor™ and MicroM families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired makeup air units and commercial hot water heaters.

Burner Controls Subcategories

BurnerLogix
BurnerLogix

The Fireye BurnerLogixTM System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection onautomatically ignited oil, gas, and combination fuel burner […]

BurnerPro
BurnerPro

BurnerPRO Flame Safeguard The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels. BurnerPRO Flame Safeguard (BP110UVF/BP230UVF) Contr […]

D‐SERIES
D‐SERIES

D-Series 70D40 and 70D41 Burner Control Fireye Series D10, D20 and D30 burner management controls provide ignition and main flame failure protection for automatically ignited oil and gas burners. Plug-in Amplifier Modules permit the selection […]

FLAME MONITOR
FLAME MONITOR

The Fireye® FLAME-MONITOR™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring pro-tection on automatically ignited oil, gas, and combination fuel bu […]

Flame Scanners
Flame Scanners

Fireye Flame Scanners provides a variety of UV and IR flame scanners that accurately detect the presence or absence of flame in a combustion chamber and some provide both self-check and non-self check capabilities.

INTOUCH
INTOUCH

The inTouch Wireless Monitoring System provides continuous monitoring for up to 10 Flame-Monitor, MicroM and/or BurnerLogix flame safeguard controls. The inTouch System provides 4 dry-contact andAC power inputs. In the event of a lockout or co […]

M‐SERIES II
M‐SERIES II

Fireye® Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use g […]

M4RT1/M4RT24
M4RT1/M4RT24

Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels. The M4RT1/M4RT24 control incorporates a safety checking circuit that is […]

MICROM SERIES
MICROM SERIES

The Fireye MicroM Series Flame Safeguard Control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment […]

NEXUS
NEXUS

Our Nexus® family of products is used in boiler applications to not only provide the flame safeguard function, but also control the entire burner operation in a manner which greatly improves efficiency and lowers operational costs. Optional va […]

Burner Controls Components

Manufacturers

Fireye YP100 Keypad selectable parameters
Fireye YP100 Keypad selectable parameters

YP100 Keypad selectable parameters, non‐recycle operation,modulation, open/closed damper proving, 4 second FFRT

Fireye YP102 Keypad selectable parameters
Fireye YP102 Keypad selectable parameters

YP102 Keypad selectable parameters, non‐recycle operation, modulation, open/closed damper proving, 2 second FFRT

Fireye YP113 Keypad selectable parameters
Fireye YP113 Keypad selectable parameters

YP113 Keypad selectable parameters, open/closed damper proving, 10 sec low fire start time, non‐recycle operation, fixed TFI times,10 pilot proving, modulation, 1 second FFRT. Required for CE applications.

Fireye YP115 Keypad selectable parameters
Fireye YP115 Keypad selectable parameters

YP115 Keypad selectable parameters, includes 0 sec purge time, fixed 0 sec low fire start time, non‐recycle operation, fixed TFI times, pilot proving, modulation, open/closed damper proving, 1 second FFRT. Required for CE applications.

Fireye YP118 Keypad selectable parameters
Fireye YP118 Keypad selectable parameters

YP118 Keypad selectable parameters, non‐recycle operation, modulation, open/closed damper proving, indefinite pilot hold, revert to pilot from auto, 1 second FFRT

Fireye YP138 Keypad selectable parameters
Fireye YP138 Keypad selectable parameters

YP138 Keypad selectable parameters, non‐recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Powered inputs provide indefinite hold, pilot hold, revert to pilot from auto.

Fireye YP183 Keypad selectable parameters
Fireye YP183 Keypad selectable parameters

YP183 Keypad selectable parameters, non‐recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Unpowered inputs provide indefinite hold, pilot hold, revert to pilot from auto. Provides purge complete output.

Fireye YP200 Keypad selectable parameters
Fireye YP200 Keypad selectable parameters

YP200 Keypad selectable parameters, recycle operation, modulation, 4 second FFRT

Fireye YP202 Keypad selectable parameters
Fireye YP202 Keypad selectable parameters

YP202 Keypad selectable parameters, recycle operation, modulation, 2 second FFRT

Fireye YP300 Keypad selectable parameters
Fireye YP300 Keypad selectable parameters

YP300 Keypad selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT

Fireye YP302 Keypad selectable parameters
Fireye YP302 Keypad selectable parameters

YP302 Keypad selectable parameters, recycle operation, low fire start, early spark termination, 2 second FFRT

Fireye 60‐2810‐1 WIRING BASE—Y MODULE
Fireye 60‐2810‐1 WIRING BASE—Y MODULE

60‐2810‐1 Pigtail wires, 4 foot long, 4″W x 5″H, color coded and labeled. UL Listed.

Fireye 60‐2812‐1 WIRING BASE—Y MODULE
Fireye 60‐2812‐1 WIRING BASE—Y MODULE

60‐2812‐1 Closed base with terminal block and knockouts, 4″W x 7″H. UL Recognized.

Fireye 60‐2814‐1 WIRING BASE—Y MODULE
Fireye 60‐2814‐1 WIRING BASE—Y MODULE

60‐2814‐1 Open base with terminal block. 4″W x 7″H UL Recognized.

Fireye 60‐2947 WIRING BASE—Y MODULE
Fireye 60‐2947 WIRING BASE—Y MODULE

60‐2947 D‐Series / E110 to YB110 Modernization Adapter